Pressure Decay
Test Methods
10-20 psig
Test Pressure
6-8 min
CYCLE TIME
0.2-0.4 psig
LEAK RATE
Manual
PASS / FAIL
- 1 Project Overview
- 2 Customer Challenges
- 3 Test Method
- 4 Instrument Selected
- 5 Results & Benefits
1
Project Overview
- Global Manufacturer of Electrical Diagnostic Instruments
- Currently Using a Pump and Pressure Manometer for Testing
- Testing Being Performed in the Engineering & Quality Lab
2
Customer Challenges
- Cycle Time > 15 min
- No Records Keeping
- Repeatability
- Reliability and Accuracy
3
Test Method
Standard Pressure Decay
The application uses a pressure decay test method with secure clamping and controlled pressurization to ensure repeatable measurements. A regulated fill, stabilization phase, and timed test period allow accurate detection of pressure loss while improving consistency and significantly reducing overall cycle time.
View Test Method4
Instrument
FP726
The ATEQ FP726 is well suited for this application thanks to its integrated pressure generator and pressure decay testing capability. Its compact design and built-in handle make the unit highly portable and easy to transport.
View Instrument5
Results & Benefits
- Cycle Time Reduced by ≈ 50%
- Portable Instrument with Internal Pressure Generator
- Test Data Logging
- Full Engineering Support