CASE STUDY DGA MONITOR

EnergyDGA MonitorPressure DecayATEQ FP726

Need leak testing for similar components?

CONTACT US
Pressure Decay
Test Methods
10-20 psig
Test Pressure
6-8 min
CYCLE TIME
0.2-0.4 psig
LEAK RATE
Manual
PASS / FAIL
  1. 1 Project Overview
  2. 2 Customer Challenges
  3. 3 Test Method
  4. 4 Instrument Selected
  5. 5 Results & Benefits
1

Project Overview

  • Global Manufacturer of Electrical Diagnostic Instruments
  • Currently Using a Pump and Pressure Manometer for Testing
  • Testing Being Performed in the Engineering & Quality Lab
2

Customer Challenges

  • Cycle Time > 15 min
  • No Records Keeping
  • Repeatability
  • Reliability and Accuracy
3
Test Method

Standard Pressure Decay

The application uses a pressure decay test method with secure clamping and controlled pressurization to ensure repeatable measurements. A regulated fill, stabilization phase, and timed test period allow accurate detection of pressure loss while improving consistency and significantly reducing overall cycle time.

View Test Method
4
Instrument

FP726

The ATEQ FP726 is well suited for this application thanks to its integrated pressure generator and pressure decay testing capability. Its compact design and built-in handle make the unit highly portable and easy to transport.

View Instrument
5

Results & Benefits

  • Cycle Time Reduced by ≈ 50%
  • Portable Instrument with Internal Pressure Generator
  • Test Data Logging
  • Full Engineering Support