D670 – HIGH SPEED FLOW TESTER

D670

HIGH SPEED FLOW TESTER FOR QUALITY CONTROL

The ATEQ D670 is a high-speed laminar flow tester that delivers rapid and accurate leak detection, embodying ATEQ’s most advanced generation of flow measurement technology. With its fully integrated measurement module, new electronic architecture, and intuitive color touchscreen, it offers unmatched test cycle speeds and user-friendly operation—ideal for high-throughput production environments. Other instruments include:

GET A QUOTE

APPLICATION

  • AUTOMOTIVE

    • Air Conditioning
    • Radiators
    • Exhaust
    • Transmission…
  • PACKAGINGS

    • Aerosol Caps
    • Plastic Bags
    • Sprays
    • Plastic Bottles...
  • ELECTRONICS

    • Hard Disk
    • Watches
    • TV Screen
    • Camera Lenses…

FEATURES

  • GENERAL

    • Flow measurement in direct or indirect testing
    • USA, S.I. and customer units
    • Measurement in standard or customized conditions
    • Recalculated flow at the nominal pressure
    • 128 programs
    • Setting on line (via USB)
    • 2 languages (English + other one)
    • Manual calibration on front panel with calibrated leak
    • Data storage on internal memory or USB key
  • TEST MODES

    • Flow units (sccm, mm³/s, cm³/s, cm³/min, cm³/h…)
    • Continuous measuring mode
  • ENVIRONMENT

    • ROHS Standard
  • FLEXIBLE COMMUNICATION FORMAT

    • RS232: Printer, Modbus RTU
    • Slave USB: USB key ti transfer data (parameters, results…)
    • Master USB: USB key to transfer (parameters, results, …)
    • Option Fieldbus: Profibus, Devicenet, Profinet, Ethernet/IP

SPECIFICATIONS

  • PHYSICAL

    • Weight: 7 Kg
    • Dimensions: (WxHxD) 540x160x380 mm
  • ELECTRICAL SUPPLY

    • 100 – 240 V AC / 50 W
  • TEMPERATURE

    • Operating: + 5°C at + 45°C
    • Storage: 0°C at + 60°C
  • INTERFACE

    • Graphic color screen with simple and intuitive menu-driven operator controls
    • SMART KEY : programmable key with user’s functions
  • AIR SUPPLY

    • Clean and dry air required
    • Air quality standard to be applied (ISO 8573-1)

OPTIONS

  • ADD-ONS

    • 9 inputs / 5 local outputs compatible with 5 series instruments
    • 6 inputs/ 6 outputs 24 V programmable for external automation
    • External capillary: closed to test port
    • Electronic regulator
    • Dual pressure
    • Automatic calibration check
    • Shut off / dumping / by-pass valve
    • 2 pneumatic outputs for control of sealing connectors
    • Memory card for archiving results (400 000)
    • Early Decision Tool for quick defect identification

TECHNOLOGY

Sometimes a leak can be considered as a “small flow”, or a flow as a “big leak”. When your reject level is too high for other technologies, it may be necessary to use a laminar flow tester. A flow takes place between the pressure line and the leak hole of the part.

Our instrument features a laminar flow element across which our differential pressure transducer is connected.

FLOW MEASUREMENT PRINCIPLE

Every flow generates a pressure difference between the inlet and outlet of the laminar flow element, and this variation is measured by the pressure transducer.

When the fluid (gas) enters the device 1, it moves through a calibrated flow tube 2 which causes a drop in pressure. The pressure drop is measured by a differential pressure sensor 3. The pressure of the part under test 5 is measured by the sensor 4.

Illustration demonstrating the laminar flow measurement principle