f600 entry level leak tester

F600

ENTRY-LEVEL LEAK TESTER FOR INDUSTRIAL QUALITY CONTROL

The ATEQ F600 is an entry-level leak tester that brings industrial-grade performance to a compact, bench‑top design. Built around standard pressure-decay technology with absolute pressure measurement, it offers high reliability and accuracy, supporting up to 128 programmable test routines and multiple test modes like flow, blockage, and sealed-part detection

GET A QUOTE

APPLICATION

  • AUTOMOTIVE

    • Air Conditioning
    • Radiators
    • Exhaust
    • Transmission…
  • PACKAGINGS

    • Aerosol Caps
    • Plastic Bags
    • Sprays
    • Plastic Bottles...
  • ELECTRONICS

    • Hard Disk
    • Watches
    • TV Screen
    • Camera Lenses…

FEATURES

  • GENERAL

    • Pressure decay leak measurement
    • Mechanical or electronic regulator from vacuum to 20 bar
    • 128 programs
    • Setting on line (via USB)
    • 2 languages (English + another one)
    • Manual calibration on front panel with calibrated leak
    • Data storage on internal memory or USB key
  • TEST MODES

    • Flow units (sccm, mm³/s, cm³/s, cm³/min, cm³/h…)
    • Blockage test
    • And others depending on your application
  • ENVIRONMENT

    • ROHS Standard
  • FLEXIBLE COMMUNICATION FORMAT

    • RS232: Printer, Modbus RTU
    • Slave USB: USB key ti transfer data (parameters, results…)
    • Master USB: USB key to transfer (parameters, results, …)
    • Option Fieldbus: Profibus, Devicenet, Profinet, Ethernet/IP
PRESSURE DROP MEASUREMENT
Test Range Delta P Range Accuracy* Max. Resolution
Vacuum

500 Pa

5 Bar

20 Bar

500 Pa (500 mbar)

1 kPa

(Vacuum, 500 mbar, 5 bar, 20 bar)

5.00 kPa

(Vacuum 500 mbar, 5 bar, 20 bar)

10.00 kPa

(Vacuum, 500 mbar, 5 bar, 20 bar)

50.00 kPa

(Vacuum, 500 mbar, 5 bar, 20 bar)

100.00 kPa

(20 bar)

± 1% Full Scale

1 Pa (500 Pa)

0.01 kPa (other)

SPECIFICATIONS

  • PHYSICAL

    • Weight: 7 Kg
    • Dimensions: (WxHxD) 255x150x270 mm
  • ELECTRICAL SUPPLY

    • 24VDC/2A
  • TEMPERATURE

    • Operating: + 5°C at + 45°C
    • Storage: 0°C at + 60°C
  • INTERFACE

    • Graphic color screen with simple and intuitive menu-driven operator controls
    • SMART KEY: programmable key with user’s functions
  • AIR SUPPLY

    • Command 4/6 bar
    • Pressure 1 or 2 bar > test pressure
    • Clean and dry air
    • Air quality standard to be applied (ISO 8573-1)

OPTIONS

  • ADD-ONS

    • 2 Pneumatic Outputs for Control of Sealing Connectors
    • Small Volume (F600 LP)
    • Small Volume & Vacuum (F600 LPV)

TECHNOLOGY

As a stripped down version of the previous technology, standard pressure decay compares the pressure on the part with the atmospheric pressure.

This technology is used when the application does not require a very high accuracy or a very fast cycle time. The method used is based on the measurement of a small variation or drop in pressure with a piezo sensor.

MEASUREMENT PRINCIPLE
 

The test pressure is applied to the input of the test part 3. The measurement is performed by the pressure sensor 2.

  1. Device
  2. Pressure sensor
  3. Part under test

DOCUMENTATION