F600HP

F600 HP

HIGH-PRESSURE LEAK TESTER FOR INDUSTRIAL QUALITY CONTROL

The ATEQ F600 HP is equipped with the technical innovations of the 6 series and allows high pressure leak testing at a very competitive price. Other instruments include:

GET A QUOTE

APPLICATION

  • AUTOMOTIVE

    • Air Conditioning
    • Radiators
    • Exhaust
    • Transmission…
  • PACKAGINGS

    • Aerosol Caps
    • Plastic Bags
    • Sprays
    • Plastic Bottles...
  • ELECTRONICS

    • Hard Disk
    • Watches
    • TV Screen
    • Camera Lenses…

FEATURES

  • GENERAL

    • Pressure decay leak testing from 5 to 1000 kPa
    • Range of measurement from 20 to 175 bar
    • 128 programs
    • Setting on line (via USB)
    • Electronic regulation 4 MPa
    • Mechanical regulation 2 MPa/ 5 MPa/ 10.0MPa/ 17.5 MPa
  • TEST MODES

    • Flow units (sccm, mm³/s, cm³/s, cm³/min, cm³/h…)
    • Desensitized Test and others, depending on your applications
  • ENVIRONMENT

    • ROHS Standard
  • FLEXIBLE COMMUNICATION FORMAT

    • RS232: Printer, Modbus RTU
    • Slave USB: USB key ti transfer data (parameters, results…)
    • Master USB: USB key to transfer (parameters, results, …)
    • 6 Inputs / 6 Outputs 24 V Programmable for External Automation
PRESSURE DROP MEASUREMENT
Pressure Range Measurement Range Accuracy up to*
5MPa Max (50 bar) 0.01 – 5.00 kPa +/- 1.0% Rdg
+ 1%FS
10 MPa Max (100 bar) 0.01 – 10.00 kPa +/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.01 – 50.00 kPa +/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.01 > 100.00 kPa +/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.1 – 500.0 kPa +/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.1 – 1000.0 kPa +/- 1.0% Rdg
+ 1%FS

Accuracy: Linearity + Repeatability + Hysteresis *Optional Laboratory Accuracy. Range from 10-100% of Full Scale

SPECIFICATIONS

  • PHYSICAL

    • Weight: 7 Kg
    • Dimensions: (WxHxD) 250x150x360 mm
  • ELECTRICAL SUPPLY

    • 24VDC/2A or 100-240VAC/50W
  • TEMPERATURE

    • Operating: + 5°C at + 45°C
    • Storage: 0°C at + 60°C
  • INTERFACE

    • Graphic color screen with simple and intuitive menu-driven operator controls
    • SMART KEY: programmable key with user’s functions
  • AIR SUPPLY

    • Command 4/6 bar
    • Pressure 1 or 2 bar > test pressure
    • Clean and dry air
    • Air quality standard to be applied (ISO 8573-1)

TECHNOLOGY

As a stripped down version of the previous technology, standard pressure decay compares the pressure on the part with the atmospheric pressure.

This technology is used when the application does not require a very high accuracy or a very fast cycle time. The method used is based on the measurement of a small variation or drop in pressure with a piezo sensor

DECENSITIZED TEST

The test pressure is applied to the input of the test part 3. The measurement is performed by the pressure sensor 2.

  1. Device
  2. Pressure sensor
  3. Part under test

DOCUMENTATION