high pressure compact leak detector

F600HP

HIGH PRESSURE COMPACT LEAK DETECTOR FOR PRODUCTION

Without any doubt the smallest high pressure leak detector on the market. The F600 HP is equiped with the technical innovations of the 6 series and allows high pressure leak testing at a very competitive price.

CONTACT US

F600HP: APPLICATIONS

  • AUTOMOTIVE

    • Air Conditioning
    • Radiators
    • Exhaust
    • Transmission…
  • PACKAGINGS

    • Aerosol Caps
    • Plastic Bags
    • Sprays
    • Plastic Bottles…
  • ELECTRONICS

    • Hard Disk
    • Watches
    • TV Screen
    • Camera Lenses…

F600HP: FEATURES

• Pressure decay leak testing from 5 to 1000 kPa
• Range of measurement from 20 to 175 bar
• 128 programs
• Mechanical regulation 2 MPa/ 5 MPa/ 10.0MPa/ 17.5 MPa
• Electronic regulation 4 MPa

TEST MODES :

Flow units (sccm, mm3/s, cm3/s, cm3/min, cm3/h…)
Desensitized Test and others, depending on your applications

ENVIRONMENT :
ROHS standard

FLEXIBLE COMMUNICATION FORMAT :

RS232: Printer, Modbus RTU
• Slave USB: PC supervision (WinAteq 300, sesame)
Master USB: USB key to transfert (parameters, results, …)
• 6 inputs/ 6 outputs 24 V programmable for external automation

Pressure RangeMeasurement RangeAccuracy up to*
5MPa Max (50 bar)0.01 – 5.00 kPa+/- 1.0% Rdg
+ 1%FS
10 MPa Max (100 bar)0.01 – 10.00 kPa+/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.01 – 50.00 kPa+/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.01 > 100.00 kPa+/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.1 – 500.0 kPa+/- 1.0% Rdg
+ 1%FS
From
2 to 20 MPa
(20 to 200 bar)
0.1 – 1000.0 kPa+/- 1.0% Rdg
+ 1%FS

Accuracy: Linearity + Repeatability + Hysteresis *Optional Laboratory Accuracy. Range from 10-100% of Full Scale

F600HP: SPECIFICATIONS

  • PHYSICAL

    • Weight: 7 Kg
    • Dimensions : (WxHxD) 250x150x360 mm
  • ELECTRICAL SUPPLY

    • 24VDC/2A or 100-240VAC/50W
  • TEMPERATURE

    • Operating: + 5°C at + 45°C
    • Storage: 0°C at + 60°C
  • INTERFACE

    • Graphic color screen with simple and intuitive menu-driven operator controls
    • SMART KEY: programmable key with user’s functions
  • AIR SUPPLY

    • Command 4/6 bar
    • Pressure 1 or 2 bar > test pressure
    • Clean and dry air
    • Air quality standard to be applied (ISO 8573-1)

F600HP: TECHNOLOGY

As a stripped down version of the previous technology, standard pressure decay compares the pressure on the part with the atmospheric pressure.
This technology is used when the application does not require a very high accuracy or a very fast cycle time. The method used is based on the measurement of a small variation or drop in pressure with a piezzo sensor.

Leak test and Desensitized Mode
The test pressure is applied to the input of the test part 3.
The measurement is performed by the pressure sensor 2.
1    Device
2    Pressure sensor
3    Part under test

F600HP: FACTSHEETS

[US] – F600 HP

[MX] – F600 HP

SUBSCRIBE TO OUR MONTHLY NEWSLETTER!

SUBSCRIBE NOW