MS-50GT HIGH-SPEED PRODUCTION CONSOLE LEAK DETECTOR

The MS-50GT is a highly technical system that incorporates many sophisticated technologies. In view of this, every effort has been made to automate the unit’s operation and maintenance procedures. The MS-50GT is an automated high-speed production console leak detector featuring three flow modes which provide flexibility and maximum productivity for application-specific leak testing.

CONTACT US

MS-50GT : APPLICATIONS

Air Conditioning & Refrigeration Systems, Automotive Components, Appliances, Aerospace, Medical Devices and others

MS-50GT: FEATURES

Technical Specifications
Vacuum Mode Direct, reverse or combination, gross testing
Roughing Pump 16 direct drive (cfm)
Foreline Pump 7 direct drive
High Vacuum  Pump 53 L/sec
Vacuum Gaughing  Pirani: Test Port and Foreline
Ion: Hihg Vacuum
Cold Trap MS-50GT- N/A
MS-50GT Dry- N/A
Power 115/50-60/30; 230-240/50-60/15
100/50-60/30 V/Hz/A
Weight 475 (215.45) lbs. (kg)
Dimensions (W x H x D):25.75 x 30.625 x 35.25
(65.40 x 77.79 x 89.54)
Test Cup, UFT
Option UFT(Ø x D)
Dimensions (in mm)
W344*H395*D618
Test Port Connection  1.125 (inches)

Main Features

  • UFT mode allowing for programmable automatic test cycle operation
  • The only production leak detector with an interactive LCD touch-screen display and GUI
  • UFT test cups (various sizes)
  • Dual pump system – dedicated Dry Foreline and Dry Roughing Pumps
  • Simple one-button power up has systems ready to test in less than 3 minutes
  • Built-in diagnostics for trouble-free maintenance
  • Fully automatic startup, tuning and calibration
  • Three Flow modes provide flexibility and maximum productivity for application-specific leak testing
  • Starts testing at Atmospheric Pressure
  • Resolution of 14 at mass 2 is twice the industry average
  • Password protection

MS-50GT: CHARACTERISTICS

Characteristics

  • Leak Measurement Range: 3.0×10-11 to 10
  • Leak Ranging: Auto/Manual
  • Response Time *: <2 direct, <2.5 reverse
  • Resolution *: 14 at mass 4
  • Gross Test, Time (with UFT Option): 3 seconds at 100 Torr
  • Fine Test, Time (with UFT Option): 10 seconds at 25 mTorr, 10-10
  • Mass Spectrometer Tube: 180° deflection; dual-magnetic sector
  • Auto-tuning: Yes
  • Auto-calibration: Internal – yes; External – auto
  • Auto-zeroing: Yes; several zeroing functions, modes for background suppression
  • Reject set-point: Yes
  • Built-in calibrated leak: Yes; 10-8 range
  • NIST traceable: Yes
  • Temperature compensated: Yes
  • Scan/Descan: Yes
  • Filaments: 2 Thoria Coated Irridum
  • Testable Masses: 3+4
  • Background Compensation: Automatic
  • Maximum Operating Pressure: 100 mTorr, 10 Torr reverse
  • Display/Interface: 10 (25.4) LCD flat panel display, capacitive touch-screen / Graphical User Interface (GUI)
  • Units: cc/second, mbar*l/second

Flexible Communication format

  • Printer Port: No
  • RS-232C: Yes
  • Software: 50 programmable test recipes; Data Link optional
PERFORMANCE
Sensitivity
vacuum*
Sensitivity
sniffing
Startup
Time
3.0×10-11
(atm-cc/sec)
10-3~10-5
Atm-cc/second
Less than
3 minutes
Vacuum System Assembly

MS-50GT: FACTSHEETS

Detailed information about the MS-50GT:  including features, specifications, etc.